The PFM function allows for the continuous monitoring of the crimping pressure or crimp diameter during production. If a parameter deviates from the programmed set range, the crimping process is immediately halted, and an alert is displayed to the operator. This enables the identification of faulty components with a high degree of certainty during production.
The monitoring system compares the crimping pressure in milliseconds and halts the crimping process immediately upon detecting a deviation. This functionality allows for the detection of double crimps, the use of incorrect crimp die diameters, the use of non-compliant components (incorrect selection of crimp sleeves, nipples, and hoses), faulty execution of hose stripping, and incomplete pre-assembly of components. All of this data is recorded and can be accessed at any time.